What Can We Do to Make Your Work Easier? Addressing the Challenges of Working with Primary Antibodies

Scientific progress is iterative. Small advances and bits and pieces of knowledge are accumulated over time with each advance depending on the body of work that has preceded it. Being able to replicate the work from one step to another in this march of science is critical, and it is not easy. We all recognize that a well-documented procedure goes a long way toward enabling reproducibility, but the procedure is not the only hurdle to reproducibility, and it’s not even the main one.

Artistic Image of Hibit Tag

Many of the reagents researchers use are derived from or produced by living organisms. A decade ago, in 2015, an analysis of preclinical research estimated that irreproducibility costs the U.S. around $28 billion a year. When the authors traced the causes, the largest single category wasn’t study design or data analysis. It was biological reagents and reference materials (1).

When Bill Linton first developed the idea of a company that supports scientists in the 1970s, his question was: “What can we do to make your work easier?” The answer he kept getting was the same: researchers wished they could buy reliable restriction enzymes instead of purifying their own for every experiment. It would reduce variability and enable them to focus on the interesting biological questions rather than the requisite protein isolations needed to ask those questions.

Biotechnology and life science research have come a long way since then. We now take reliable, commercially available restriction enzymes for granted. Still, Promega keeps asking Bill’s original question: What can we do to make your work easier? The answers to that question have led to ground-breaking luciferase reporter technology, add-mix-measure assays for everything from cell viability to P450 activity to NADP/H detection, and standardized thaw-and-use primary cell lines for bioassays.

Today’s Difficult Reagent: Primary Antibodies

Among the most difficult reagents to work with and standardize are antibodies. If you are generating polyclonal primary antibodies that are not commercially available to study your target protein, you first need to find an animal with clean pre-immune serum. Usually that serum is evaluated by Western blot, which itself is an inherently fussy technique. And polyclonal antibodies are just that—polyclonal. What is generated after exposure to your antigen is a mixture of antibodies, and the composition of the mixture can change over time as the animal’s immune response matures. This gives you batch-to-batch variability and can make reproducibility more difficult. Commercially produced polyclonal antibodies are subject to the same exact issues. In August 2026, a news article in Nature reported that a metascientist had released a database of more than 18,000 questionable validation images across the catalogs of 15 antibody suppliers. All reflect the antibodies may not be performing like the scientists expect (Garisto 2026). Additionally, production of antibodies requires animal resources. High-quality, application validated antibodies are expensive as well. Using primary antibodies to study proteins is a significant pain point for the bench scientist.

It’s Not Just the Antibodies. It’s the Western Blots Too.

Tagged proteins or high-abundance exogenous expression of a target protein will not always reflect the endogenous protein behavior, localization or function. Large tags can interfere with folding and function; over expression of a protein can produce false protein interactions. Your results could be showing you artifacts resulting from a situation in your cells that is simply not biologically relevant.

If you are studying your target proteins (and other molecules) using Western blotting, post-translational modifications such as phosphorylation, ubiquitination, and cleavage shifts can complicate the interpretation of your results. Multiple bands on a blot can be hard to understand—is the protein cleaved? Is there cross-reactivity with your antibody to another protein? Is your sample degraded?

Continue reading “What Can We Do to Make Your Work Easier? Addressing the Challenges of Working with Primary Antibodies”

Live-Cell Imaging: It’s Time to See What Else Your Luminescence Assays Can Tell You

luminescent cells behind a molecular structure

Luminescent live-cell assays are powerful tools for cellular biology research. They offer both qualitative and quantitative insights into processes such as gene expression, cell viability, metabolic activity, protein and small molecule interactions, and targeted protein degradation. But what if you could go beyond the numbers and actually see what is happening in your cells? With luminescent imaging, you have the opportunity to uncover more dynamic data by visualizing what happens with your cells in real time.

Why Luminescent Imaging?

Bioluminescent reporters such as NanoLuc® luciferase are well-suited for bioluminescent imaging. NanoLuc, the smallest engineered luciferase available, is up to 150X brighter than firefly or Renilla luciferase, so exposure times can be shorter than they would be with other luminescent reporters. Its small size also makes it less likely to perturb normal biology or protein function.

Another benefit of bioluminescence for imaging is the inherent stability and sustainability of the bioluminescent signal, which does not require external excitation like fluorescent tags.  This allows direct visualization of protein dynamics in living cells without the need for repeated sample excitation. The lack of external excitation also reduces the risk of phototoxicity and photobleaching, common issues that can adversely affect cell viability and signal integrity over time.

Applications Across Cellular Research

Luminescent imaging complements traditional luminescence assays by adding spatial and temporal dimensions. With luminescent live-cell imaging, researchers can visualize NanoLuc® Luciferase assays to gain a deeper understanding of the real-time cellular processes occurring in each experiment. Applications include:

  • Determining which cells provide signal
  • Analyzing mixed cell populations
  • Identifying rare events
  • Monitoring protein:protein interactions
  • Identifying protein localization and translocation
  • Tracking protein degradation and stability over time
  • Visualizing ligand:protein interactions (target engagement)

Luminescent Imaging in Action

Targeted Protein Degradation

Selectively targeting proteins for removal from the cell—instead of inhibiting protein activity—is a newer approach with therapeutic potential. In this method, the protein is targeted for degradation using the cell’s natural ubiquitin proteasome system (UPS). The degradation process is initiated by compounds such as molecular glues and proteolysis targeting chimeras (PROTACs) linking the target protein to an E3 ligase. Once this linkage occurs, the cell’s UPS does the rest.

Luminescent substrates with increased signal stability, such as the Nano-Glo® Extended Live Cell Substrate, enable researchers to image targeted protein degradation in their cells in real time. In the example shown below, Nano-Glo® Vivazine™ Live Cell Substrate was used to image degradation of the GSPT1 protein by the CC-885 degrader over 5 hours.

gif showing luminescent signal disappearing with protein degradation

Targeted protein degradation over time. HEK293 cells expressing endogenous HiBiT-tagged GSPT1 and stably expressing LgBiT were treated with CC-885 degrader or DMSO control treatment. Assayed with Nano-Glo® Vivazine™ Live Cell Substrate and imaged over 5 hours using GloMax® Galaxy Bioluminescence Imager.

Combining Luminescent and Fluorescent Imaging to Detect Protein:Small Molecule Interactions

Using bioluminescence resonance energy transfer (BRET)-based assays such as NanoBRET® assays allows you to detect protein:protein interactions by measuring energy transfer from a bioluminescent protein donor to a fluorescent protein acceptor. These assays can be used to monitor changes in protein interactions over time, making them a useful tool for small-molecule screening.

The schematic below illustrates how the NanoBRET® NanoGlo® Detection Systems can be used to visualize target engagement. The cells on the left are expressing a NanoLuc® fusion protein, resulting in a luminescent signal. Adding a fluorescent small tracer (center) results in energy transfer and a fluorescent signal (right). Using an imaging platform that has luminescence and fluorescence imaging capabilities will let you see this energy transfer in action.

schematic showing cells detected by luminescent and fluorescent imaging
Detecting protein:small molecule interactions with NanoBRET® NanoGlo® Detection Systems.  HCT116 cells expressing a PRMT5–NanoLuc® fusion were supplemented with a fluorescent small molecule tracer (center panel). Before tracer addition, luminescent signal indicates energy is present on the donor protein (left; 3-minute exposures for 15 minutes). Binding of fluorescent tracer results in energy transfer and fluorescent signal (right; 3-minute exposures for 60 minutes). Images were captured on the GloMax® Galaxy Bioluminescence Imager.

Bringing the Power of Luminescent Imaging to Your Lab

glomax galaxy imager and computer screen

The GloMax® Galaxy Bioluminescence Imager was built to visualize the NanoLuc®-based assays we engineered, in a benchtop instrument accessible to any lab. The Galaxy is a fully equipped microscope with luminescence, fluorescence, and brightfield imaging capabilities, giving researchers a way to see functional and dynamic cellular events across a cell population.

Conclusion

Luminescent imaging can enrich what we learn from live-cell assays and offers an unprecedented view into the dynamics of cellular processes. From monitoring drug responses to visualizing protein interactions, this technology delivers insights that go beyond the capabilities of traditional assays.

Whether you’re studying cancer biology, drug development or cellular signaling, luminescent imaging can help you uncover what’s hidden in your data and see your research in a whole new light.

Additional Resources

GloMax® Galaxy Luminescent Imager, NanoBRET® Nano-Glo® Detection Systems and Nano-Glo® Vivazine live Cell Substrate are for Research Use Only. Not for Use in Diagnostic Procedures.